Slump test procedure pdf download

Nd t 121 density unit weight, yield, and air content gravimetric of concrete. After the material is introduced into the water, the mixing speed in increased from 1,200 rpm to 15,000 rpm for 1 minute. Procedure of slump flow test on self compacting concrete. More is the slump value more will be the workability. Thoroughly mix the sample by shovelling to form a cone on the. Fill cone full by volume and rod 25 times with 58inchdi ameter x 24inch long hemispherical tip steel tamping rod. Find powerpoint presentations and slides using the power of, find free presentations research about slump test ppt. Concrete slump test uji slump beton sharing materi. Commence the slump test as soon as possible after sampling of concrete as per standard procedure described in chapter 2.

In order to promote public education and public safety, equal justice for all, a better informed citizenry, the rule of law, world trade and world peace, this legal document is hereby made available on a noncommercial basis, as it is the right of all humans to. A sample is poured into a mini slump cone, rodded, struck off, and lifted at 2 minutes. Pdf selfcompacting concrete procedure for mix design. Concrete slump test is carried out from batch to batch to check the uniform quality of concrete during construction. It is not a suitable method for very wet or very dry. Normal neurodynamic responses of the femoral slump test. Empty the sample from the container onto the sampling try. The flow table test procedure does not conform with astm standard and is as follows. Begin and complete slump test within 212 minutes, maximum.

The sensitivity and specificity of the slump and straight leg raised tests in patients with lumbar disc herniation. Slump test slump test is the most commonly used method of measuring consistency of concrete which can be employed either in laboratory or at site of work. View and download powerpoint presentations on slump test ppt. A concrete batch with high slump is an indication that the concrete has to. A concrete slump test is used to determine the correct water content in a batch of concrete. Description download bs en 123502 2009 testing fresh concrete. The tamping rod is of steel 16 mm diameter and 60cm long and rounded at one end. The slump flow test is used to assess the horizontal free flow of scc in the absence of. The concrete slump test is known as standard test method for slump of hydrauliccement concrete and carries the code astm c 143 or aashto t 119. If this test is being carried out in the field, the sample mixed concrete shall be obtained. The test methods used should be simple, direct and convenient in their application.

Because of it, it has been extensively applied for workability tests since 1922. Lab manual of concrete technology sanjay ghodawat group of. If you are thinking about the slump test, you are thinking that the neuromeningeal interface is underpinning signs and symptoms. It states in the procedure that when the cone is removed, it should be lifted up vertically, without any rotational movement at all. Standard test method for slump of hydraulic cement concrete. Standard test method for slump flow of selfconsolidating concrete. The slump test is a practical means of measuring the workability. Test procedure the original mini slump cone test procedure uses a 600 gram sample. Slump flow test on self compacting concrete for workability. Standard test method for slump of hydrauliccement concrete 1. Fill onethird of the slump cone and tamp 25 times with a rod.

Maitlands slump test is a widely used neural tissue tension test. The astm standards also regulate the rigidity of the cone. The water content was adjusted to compensate for the dry gravel and sand used in the lab. Concrete slump test for workability procedure and results. This method of test specifies the procedure to be adopted. Procedure record all information on sfn 9987 or sfn 2455. To measure the consistency of concrete by using slump cone apparatus required. The mini slump test is a variation of the slump test with reduced size.

Slump test is the most commonly used method of measuring consistency of concrete which can be employed either in laboratory or at site of work. Changes in the value of slump obtained during a job may indicate changes in. The mould is placed on a flat moist nonabsorb surface with the smaller opening at the top. Estimating concrete workability based on slump test with. American society for testing and materials astm standards are astm c 143 or astm c143m. The concrete slump test is an onthespot test to determine the consistency as well as workability of fresh concrete. It is not a suitable method for very wet or very dry concrete. Reproducible minislump test procedure for measuring the yield stress of cementitious pastes article pdf available in materials and structures 506 december 2017 with 1,027 reads. Slump test is the most commonly used test of measuring workability of concrete. A small variation in slump caused by improper procedure or equipment, may cause the rejection of an entire.

How to build and setup a concrete foundation for garages, houses, room additions, etc part 1 duration. Reproducible minislump test procedure for measuring. If the slump test fails to meet the range limit as dictated by the british standard shown in the table below then the load should be rejected. It is used conveniently as a control test and gives an indication of the uniformity of concrete from batch to batch.

Reproducible mini slump test procedure for measuring the yield stress of cementitious pastes article pdf available in materials and structures 506 december 2017 with 1,027 reads. The sampling and the test is performed under the following rules and laws. The test is popular due to the simplicity of apparatus used and simple procedure. This standard has been prepared with this object in view. Slump test procedure and sheet free download as pdf file. An astm designation number identifies a unique version of an astm standard. You have to clean all the apparatus which is going to use with water and then apply the oil on the surface to make then frictionfree. The slump test is the most common method for assessing the flow properties of fresh concrete. More specifically, it measures consistency between batches. Measure slump from the top of the mold to the displaced original center of the concrete. And more importantly, the stepbystep procedure of slump test followed by the list of cautions during the test and way to measure the workability from the test result. The test only measure present of water in concrete and workability. The slump is carried out as per procedures mentioned in astm c143 in the united states, is.

It can be employed either in laboratory or at site of work. Site testing slump test always do your slump test before making your cubes to ensure the concrete is usable. Active standard astm c143 c143m developed by subcommittee. Additional information on workability and quality of concrete. Slump cone 200 mm diameter for bottom opening 100 mm diameter for top opening. Moisten the base plate and inside of slump cone, place base plate on level stable ground and the slump cone centrally on the base plate and hold down firmly. The test is an empirical test that measures the workability of fresh concrete. More specifically, it measures concrete consistency between batches. Astm c143 c143m 15a standard test method for slump of. This is a test required to pass the american concrete institute aci.

Using this test, the slump can be derived by measuring the drop from the top of the slumped fresh concrete. The mold for the test is in the form of the frustum of a cone having height 30 cm, bottom diameter 20 cm and top diameter 10 cm. Overview of astm c143 standard test method for slump of hydrauliccement concrete. Sharing materi perkuliahan teknik sipil untuk mengembangkan blog ini, mohon pembaca memberikan komentar dan sharing ke media social lainnya seperti facebook dan twitter. The concrete slump test is used for the measurement of a property of fresh concrete.

Pdf reproducible minislump test procedure for measuring. The sample size required for this test is a minimum after drying. The slump test is treated as the most easy workability test toward concrete that offers low cost and instant results. About 6 liter of concrete is needed to perform the test, sampled normally. Slump is the distance, measured in inches, the concrete settles after the slump cone is removed. Slump test procedure and sheet concrete building engineering. The slump is done following the methods described in astm c143 in the united states, is. Here are the steps to do the slump test of concrete. B view of the mold, the rod attached to the base and the top plate at the final position. The internal surface of the mould is thoroughly cleaned and freed from superfluous moisture and adherence of any old set concrete before commencing test. It is the most common method for measuring the workability of freshly mixed concrete.

Introduction slump test used for the measurement of a property of fresh concrete. Wsdot fop for astm c 1621c 1621m1 standard test method for passing ability of selfconsolidating concrete by jring. Concrete having a different mix m15 or m20 etc with the suitable watercement ratio and can be prepared at the site or casting the 6 cubes after conducting the slump test. This tests results can be interpreted in multiple ways. The slump test is perhaps the most widely used because of the simplicity of the apparatus required and the test procedure. It is then held firmly in place during filling of concrete by the operator standing on two foot pieces. Concrete slump test or slump cone test is to determine the workability or consistency of concrete mix prepared at the laboratory or the construction site during the progress of the work. Recently, physical therapists have become quite conservative with this test, opting for slidinggliding rather than outright stretching.

Fill cone full by volume and rod 25 times with 58inchdi ameter x 24inchlong hemispherical tip steel tamping rod. If this test is being carried out in the field, the sample mixed concrete shall be. Uniformity of the concrete regarding workability and quality aspects can be assessed from batch to batch by observing the nature in. Slump test is the most commonly used method of measuring consistency or workability of fresh concrete which can be employed either in laboratory or at the site of work. Pdf reproducible minislump test procedure for measuring the. Astm c143 standard test method for slump of hydraulic. Tests on concrete workability tests slump cone test, compaction factor test. Test procedures, sometimes simplified because of time limitation, are. When a truck mixer reaches the checkpoint, the quality engineer should check the delivery note to ensure that the concrete delivered is in compliance with the concrete grade required for the concrete element to be cast. It is used conveniently as a control test and gives an indication of the uniformity of the concrete from batch to. Procedures for slump test step by step the whole concrete slump test is performed under the 5 steps. Astm c143 aci slump test of hydraulic cement concrete. Slump test for concrete to determine its workability. Astm c143c143m15a standard test method for slump of.

1586 1217 1 1051 1461 1556 226 1207 1335 1090 1063 1611 1646 1501 49 480 83 10 828 706 1188 1138 154 102 939 308 1148 723 1260